AMJ-302 Hospital Regular Anesthesia Ventilator Machine With Gas Source

AMJ-302 Hospital Regular Anesthesia Ventilator Machine With Gas Source AMJ-302 Hospital Regular Anesthesia Ventilator Machine With Gas Source

Integrated breathing circuit with APL valves, good sealing, easy to use. Low basic resistance, good mechanical compliance. Do not need to replace the drive bellows when operating the child anesthesia. The drain cup is designed to ensure that there is no water in the breathing path. Built-in design dual flow sensor (no maintenance). 2 L large capacity CO2 can. High ends 134 ° C.

Quantity:
Share this:
  • Product Description
  • Parameter

Hospital Regular Anesthesia Ventilator Machine With Gas Source Features:

1.12.1 inch touch screen with no dead space.
2.NEW interface design with user friendly layout and colour assortment.
3.Day/Night display mode brings a better visual perception to users. Night mode suitable for dark environment.
4.To display a full range of ventilation modes including VCV, PCV, SIMV-V, SIMV-P, PSV etc. Also displays pressure, flow, volume and CO2 waveform in same interface.
5.Real-time detection for loops, airway pressure, flow rate, volume, compliance and airway resistance.
6.Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
7.Typical display for Zoom in/out, comparison, freeze.
8.Event logging function.
Integrated Breathing Circuit
1.Integrated breathing circuit with APL valve, excellent tightness and easy to use.
2.Low essential resistance, good mechanical compliance.
3.Replacing drive bellow is not required when operating pediatric anesthesia.
4.Drain cup design ensure no water trap in the breathing circuit.
5.Built-in design duo flow sensor (no maintenance required).
6.2 L Large volume of CO2 canister.
7.Autoclave 134 °C.
High-precision Vaporizer
1.New vaporizer can be used for large flow anesthesia(15L/Min).
2.Apply automatic compensation function for temperature, pressure and flow.
3.Apply Interlock Selectatec.
4.Pour type: Isoflurane, Enflurane,Halothane, Sevoflurane.
ACGO
1.International standard design.(diameter:22mm).
2.Convenient for patients'oxygen inhalation and postoperative recovery.
3.To connect with T circuit or bain circuit for open-operation.
AGSS
1.Made by aluminum alloy. High strength, light weight, never rusts.
2.Enhance the safety of the environment in which members of staff in close proximity with waste anaesthetic gases and vapors (agents) work.
Yoke system
1.Up to 3 back up cylinders with A-type 11L size.

Technical Specifications

Physical Specifications

Dimensions:

70*85*140cm

Weight:

65kg

Casters:

Front wheels with lock

Screen:

12.1 inch LCD

Working Specifications

Power

AC 220V±10%, 50Hz±2%

Pipeline Supply

Gas configuration

O2, N2O, Air

Pipeline input range

280-600kPa

Battery Power

Run-time

2180 mins

Pre-setting Functions

Language

English

Calibration

Automatic

Applications

Patient range

Audit/ Pediatric

Ventilator Specifications

Modes of Ventilation

vcv

Volume Controlled Ventilation

SIMV-V

Synchronized Intermittent Mandatory Ventilation-Volume

SIMV-P

Synchronized Intermittent Mandatory Ventilation-Pressure

MANUAL

Manual

A/C

Assist /control Ventilation

PCV

Pressure Control Ventilation

PSV

Pressure Support Ventilation

STAND-BY

STAND-BY

Ventilator Parameter

Working type

Electronic control, pneumatic driven

Tidal Volume range

20-1500ml

Pressure range

5-60 cmHaO

Rispriation rate range

1-100 bpm (1-40bpm under SIMV)

l:E range

4:1-1:8

Ptrigger range

-20-20 cmHzO (based on PEEP)

Flow trigger

0-15L

Minute volume range

>18L/Min

SIGH range

0-5/100

System Standard

Hypoxic guard system

N2O cut-off valve, O2 concentration >25%

Safety valve

<12.5kPa

Fresh gas compensation

25-75L/min

Volume of CO2 absorber

2 L

Flow meter

5 tubes, Cascade 0.1-15L/min O2


0.1-15L/min N2O, 0.1-15L/min air

Vaporizer

2 Selectetac, maximum 2 mounts(lsoflurane/Enflurane/Sevoflurane/Halothane)

Monitoring

Display graphics

Waveforms of P-T, F-T, V-T, loops of P-V,V-F,F-P(Zoom in/out, comparison, freeze)

Types

VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform,F1O2

Alarm Limits

Audio/Visual

No tidal volume, MV,Paw, FiO2 limitation O2,


Air failure, AC power failure, Battery low

PEEP

Type

Integrated, Electronic control

Range

OFF, 3-30cmH2O

Optional

1.AGSS

Anesthetic Gas Scavenging Systems

2.Suction Unit

3.Communication Interface

Ethernet, USB, VGA

4.Auxiliary Oxygen meter


×