Brief Introduction:
Two control modes: Air mode and baby mode controlled by micro-computer; Humidity control system;
Set temperature, air temperature, baby temperature, humidity and oxygen are displayed separately;
>37℃ temperature set function;
Failure alarm indication;
Embedded integrated sensor box;
Integrated water reservoir in the shape of drawer;
Double wall hood, automatic air circulation device;
Inclination of bassinet is adjustable;
RS-232 connector;
DC motor.
Standard Configuration:
Optional Configuration:
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90 (with blue fluorescent lamps)
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L (with LED blue lights)
Vertical height adjustment stand (VHA stand) Weighing system, Disposable skin temperature sensor and SP02.
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA
Mode of control: Air mode and baby mode controlled by micro-computer
Air temperature control range: 25℃ -37℃ (override mode 37-39℃ )
Baby temperature control range: 34-37℃ (override mode 37-38℃ )
Accuracy of skin temperature sensor: ±0.2℃
The temperature difference between incubator temperature and average incubator temperature(under steady temperature condition)≤0.5℃
Temperature uniformity: 0.8℃ (mattress is on the horizontal position)
Inclination of the bassinet: ±12°
Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm , low water alarm , tank position alarm and system alarm.
Humidity display range: 0%RH-99%RH
Humidity control range: 0%RH-90%RH
Accuracy of humidity display: ±5%RH(environment temperature is 25℃ , environment humidity is 45%RH±5%RH)
Indication range of oxygen concentration: 0%-99%
Control range of oxygen concentration: 20%-60% ( for HB-YP970 )
Accuracy of oxygen display concentration: ±2%(oxygen concentration sets 25%) ±3%(oxygen concentration sets >25%)
Environmental temperature:
Operating range: 20℃ -30℃ (Set temperature should be higher 3℃ than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging:
Package:each unit is packed into two cartons
Dimension (Main body): 1085mm x 640mm x 915mm
(Cabinet): 1125mm x 665mm x 730mm
Gross Weight (Main body):66Kg
(Cabinet): 60Kg

HB-YP930 Hospital Medical Equipment Premature Baby Care Infant Incubator
Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached.
Get a Quete
Request More Information
Related Products
HB-YP2008 Medical Hospital Delivery Room Newborn Baby Infant Incubator
HB-YP100B Hospital Use New Born Baby Incubator Medical Infant Incubator
HB002 China Manufacturer Newborn Baby Care Medical Infant Incubator
HB4500 Medical Infant Incubator Infant Care Equipment
HB-YP90AC Nursing Hospital Baby Premature Newborn Infant Incubator
HB-YP910/HB-YP920 Medical Baby Care Incubator Premature Newborn Infant Baby Incubator
HB-YP100 Emergency Apparatus Medical Rescue Transport Infant Incubator
HB-YP100A /YP100AB Medical Hospital Premature Baby Care Newborn Infant Incubator
HB-YP90B Hospital Premature Baby Care Newborn Infant Incubator
HB-YP970 Medical Four Wheels ICU Delivery Room Baby Neonatal Infant Incubator
HB-YP90 Light Weight And Easily Transportable Transport Baby Incubator
HB-YP2000 Portable Baby Infant Incubator for Sale
HB-YP90AB Hospital ICU Equipment Baby And Infant Incubator
HB-YP90A Medical Equipment Good Quality Low Price Medical Transport Baby Incubator For Sale
HB2000 NICU Warmer Neonatal Transport Incubator With Ventilator
HB103 Medical Infant Incubator Baby Caring Equipment In Hospital
HB101 Medical Hospital Infant Incubator Newborn Incubator