Brief Introduction:
Two control modes: Air mode and baby mode controlled by micro-computer
Humidity concentration display system
Set temperature, air temperature, baby temperature, humidity concentration are displayed separately;
>37℃ temperature set function;
Failure alarm indication;
Embedded integrated sensor box
Double wall hood, automatic air circulation device;
Inclination of bassinet is adjustable;
RS-232 connector;
Oxygen input interface;
DC motor.
Standard Configuration:
HB-YP910: The hood, the base, the mobile cabinet, the controller, I.V pole, tray.
HB-YP920: The hood, the base, the mobile cabinet, the controller, I.V pole, tray, with Humidity control system.
Optional Configuration:
Fixed neonate bilirubin phototherapy equipment model:HB XHZ-90 (with blue fluorescent lamps);
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L (with LED blue lights);
Vertical height adjustment stand (VHA stand), Weighing system , SPO2 and Disposable skin temperature sensor.
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA ( HB-YP910 )
Power requirement:AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA (HB-YP920)
Mode of control: Air mode and baby mode controlled by micro-computer
Air temperature control range: 25℃ -37℃ (override mode 37-39℃)
Baby temperature control range: 34-37℃ (override mode 37-38℃ )
Accuracy of skin temperature sensor: ±0.2℃
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition)≤0.5℃
Temperature uniformity≤0.8℃ (mattress is on the horizontal position)
Inclination of the bassinet: ±12° la Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm and system alarm. (HB-YP920 has low water alarm and tank position alarm)
Humidity display range: 0%RH-99%RH
Accuracy of humidity display: ±5%RH(environment temperature is 25℃ , environment humidity is 45%RH±5%RH)
Environmental temperature:
Operating range: 20℃-30℃ (Set temperature should be higher 3℃ than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging:
Package: each unit is packed into two cartons
Dimension (Main body): 1085mm x 640mm x 910mm
(Cabinet): 1125mm x 665mm x 725mm
Gross Weight (Main body):63Kg (for HB-910)
Gross Weight (Main body):66Kg(for HB-920)
(Cabinet):68Kg

HB-YP910/HB-YP920 Medical Baby Care Incubator Premature Newborn Infant Baby Incubator
Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached.
Get a Quete
Request More Information
Related Products
HB-YP2008 Medical Hospital Delivery Room Newborn Baby Infant Incubator
HB-YP100B Hospital Use New Born Baby Incubator Medical Infant Incubator
HB002 China Manufacturer Newborn Baby Care Medical Infant Incubator
HB4500 Medical Infant Incubator Infant Care Equipment
HB-YP90AC Nursing Hospital Baby Premature Newborn Infant Incubator
HB-YP930 Hospital Medical Equipment Premature Baby Care Infant Incubator
HB-YP100 Emergency Apparatus Medical Rescue Transport Infant Incubator
HB-YP100A /YP100AB Medical Hospital Premature Baby Care Newborn Infant Incubator
HB-YP90B Hospital Premature Baby Care Newborn Infant Incubator
HB-YP970 Medical Four Wheels ICU Delivery Room Baby Neonatal Infant Incubator
HB-YP90 Light Weight And Easily Transportable Transport Baby Incubator
HB-YP2000 Portable Baby Infant Incubator for Sale
HB-YP90AB Hospital ICU Equipment Baby And Infant Incubator
HB-YP90A Medical Equipment Good Quality Low Price Medical Transport Baby Incubator For Sale
HB2000 NICU Warmer Neonatal Transport Incubator With Ventilator
HB103 Medical Infant Incubator Baby Caring Equipment In Hospital
HB101 Medical Hospital Infant Incubator Newborn Incubator