HBHKN-2001 Medical Hospital Clinic Baby Care Infant Neonate Radiant Wamer

HBHKN-2001 Medical Hospital Clinic Baby Care Infant Neonate Radiant Wamer HBHKN-2001 Medical Hospital Clinic Baby Care Infant Neonate Radiant Wamer

Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached.

Quantity:
Share this:
  • Product Description

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand.
Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, J.V. Pole, mattress, tray and panels
Specification:
Power requirement: AC22OV-230V/5OHz or AC11O-120V/50-6OHz, 900VA  Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro - computer
Baby mode temperature control range: 34.5-37.5℃
Accuracy of skin temperature sensor: ±0.2℃
Temperature uniformity of mattress: 2℃
Mattress heating control range: 25-38℃
Accuracy of mattress temperature display: ±0.7℃
Angle of warmer module: ±60℃
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50°~ 1°, 4°50° ~5°, 9° 50°~ 10°
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: 1mW/cm2
Average value general bilirubin radiation of on the mattress effective range: 0.8mW/cm2
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Environmental Temperature:
Operating range: 18 °C -30°C
Ambient air movement rate:
Product Packaging:
Package: each unit is packed into one carton
Dimension: l500mmx8l0mmxl475mm
Gross Weight: 250 Kg

×